ZyZyX USA

Reusable Handle

$49.95

Product Overview

Essential Non-Disposable Component

The reusable handle is the core component of the ZyZyX Universal Positioning System. It houses the USB cable for better control and features our patented keyed shaft technology for improved positioning and patient comfort.

Key Features

Keyed Shaft Technology

Non-round design prevents unwanted rotation and allows comfortable patient bite

Non-Slip, Non-Porous Design

Secure grip and easy to sterilize between patients

Reversible Attachment

Can be inserted from either side for versatile positioning

Cable Management

Houses USB cable for better control during procedures

No Metal Components

Completely invisible to X-Ray - no artifacts

Universal Compatibility

Works with all sensor sizes (0, 1, 1.5, 2)

Technical Innovation

Keyed Shaft Benefits

  • Prevents unwanted rotation during imaging
  • Allows patients to bite comfortably without slippage
  • Enables sensor to be angled further for optimal positioning
  • Improved control during challenging procedures

Material Properties

  • Special non-toxic composite material
  • Sterilizable (may show slight discoloration - normal)
  • Non-porous surface prevents bacteria buildup
  • Durable construction for long-term use

Clinical Benefits

Enhanced Control

Better grip and control during imaging procedures with cable management

Time Savings

Quick setup and no need to remove rubber dams for X-rays

Patient Comfort

Allows comfortable bite positioning without sensor rotation

Versatile Positioning

Reversible design works for all quadrants and angles

Usage Instructions

  1. 1

    Thread sensor USB cable through the handle for cable management

  2. 2

    Attach appropriate disposable flag (FL-1 or FL-2) to the handle

  3. 3

    Apply flag to sensor's plastic barrier sleeve (never directly to sensor)

  4. 4

    Position for desired quadrant - handle can be reversed if needed

  5. 5

    After use, dispose of flag and sterilize handle for next patient

Maintenance & Care

Sterilization

  • Compatible with standard sterilization methods
  • May show slight discoloration after sterilization (normal)
  • Non-porous surface ensures thorough cleaning
  • Follow your facility's standard sterilization protocols

Best Practices

  • Always use with disposable flags (never reuse flags)
  • Inspect handle before each use
  • Store in clean, dry environment
  • Replace if any damage or wear is observed

System Compatibility

Universal Compatibility

Works with all major dental imaging systems and sensor sizes (0, 1, 1.5, 2)

Compatible systems include: Care Stream / Kodak, Schick Sirona, Dexis, Gendex, Suni, VaTech, XDR, and many more including Apex, ATECO, Cygnus, Sopro, Yes BioTech

Quality Assurance

Field Tested

3+ years clinical use

University Validated

Clinical Staff approved

Patented Design

Board-certified developed

USA

Made in USA

ISO Class 8 Specs

Complete Your System

Essential Component

The reusable handle requires disposable flags to function. Consider purchasing:

25x FL-1 ULLR FlagsFor Upper Left/Lower Right positioning
25x FL-2 URLL FlagsFor Upper Right/Lower Left positioning